MODIS IOT Aqua Weekly Report
Mission Operations Days: 2002/145 to 2002/151
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
PM-1 "Aqua" is in Fine Pointing Standby Mode FM1 MODIS is Outgassing in B-Side Standby Mode |
||
| Component | State(s) | Comment |
|---|---|---|
| Blackbody | A Off; B Off | Standby Mode (with Outgas) |
| Calibration Electronics | A Off; B Off | Standby Mode (with Outgas) |
| Control Processor | A Off; B On | Standby Mode (with Outgas) |
| Nadir Door | Unlatched, Closed | Standby Mode (with Outgas) |
| Space View Door | Unlatched, Open | Standby Mode (with Outgas) |
| Solar Diffuser Door | Unlatched, Closed | Standby Mode (with Outgas) |
| FDDI Formatter | A Off; B Off | Standby Mode (with Outgas) |
| FDDI Port | A Off; B Off | Standby Mode (with Outgas) |
| FIFO Memory | #1 & #2 Off; #3 & #4 Off | Standby Mode (with Outgas) |
| Format Processor | A Off; B Off | Standby Mode (with Outgas) |
| Power Supplies | #1 Off, #2 On | Standby Mode (with Outgas) |
| PV VIS FPA | A Off; B Off | Standby Mode (with Outgas) |
| PV NIR FPA | A Off; B Off | Standby Mode (with Outgas) |
| PV SMIR FPA | A Off; B Off | Standby Mode (with Outgas) |
| PV LWIR FPA | A Off; B Off | Standby Mode (with Outgas) |
| PC LWIR FPA | A Off; B Off | Standby Mode (with Outgas) |
| RC Outgas Heaters | All 3 (CS, IS, OS) On | Standby Mode (with Outgas) |
| RC LWIR FPA Heater | Off | Standby Mode (with Outgas) |
| RC SMIR FPA Heater | Off | Standby Mode (with Outgas) |
| Scan Assembly | A Off; B Off | Standby Mode (with Outgas) |
| SDSM | Off | Standby Mode (with Outgas) |
| SRCA | Off | Standby Mode (with Outgas) |
| PS1 Survival Heaters | Enabled | Standby Mode (with Outgas) |
| PS2 Survival Heaters | Enabled | Standby Mode (with Outgas) |
| Timing Generator | A Off; B Off | Standby Mode (with Outgas) |
| Flight Software | Rev BJ | Standby Mode (with Outgas) |
| Inhibit Ids Set | None | Standby Mode (with Outgas) |
None
Sunday, May 26, 2002None
Monday, May 27, 2002None
Tuesday, May 28, 2002None
Wednesday, May 29, 2002
2002/149 21:23:26 - 21:26:00 Real-Time Loaded Macro 31. MOD_MEM_PM_LOAD('PM1_MPR_MOD_111_SCIF_TEST',481,'N','DISABLE',1,16)
2002/149 21:26:24 - 21:30:05 Real-Time Dumped Macro 31 Table (not completed due to time constraint. MOD_MEM_DUMP('MACRO_31',481,0,0,1,16)
2002/149 22:51:42 - 22:51:57 Real-Time Halted memory transfer. MOD_MEM_HALT
2002/149 22:52:22 - 22:52:58 Real-Time Dumped last partition of Macro 31. MOD_MEM_PM_DUMP('MACRO_31',481,0,0,16,16)
None
Friday, May 31, 2002
2002/151 22:03:42 - 22:06:12 Real-Time Moved the SVD to Open (from Outgas) Position. MOD_SVD_TO_OPEN
2002/151 22:25:27 - 22:26:05 Real-Time Dumped the CP Door Position when Trigger Hit Table. MOD_MEM_PM_DUMP('MOTOR_POS_WHEN_HIT', 12, 0, 0, 1, 1)
The first Delta-V maneuver was successful but less effective than expected. Planning has begun for the next Delta-V.
Current Ascent Plan (as of May 24, 2002):Since the second MODIS turn ON activity on DOY 144, there have been 19 pairs of 5D/77 CP event messages received. 5D is the TLM Format/Collect Mismatch message, and 77 is the TLM Late Telemetry Formatting message. SBRS says they have seen these messages during Thermal Vac (around CDH bus activities). The 5D message occurs when something upsets the sector timing or the CP. Since the 5D and 77 are coming together, there may be something going on with the 1553 bus. The events are shortly followed (within 5 seconds) by a telemetry packet with the same MOD_SS_CP1553_MAJCYC value. However, "it appears that the telemetry in said packet is a second reporting of the prior packet, with updates in the one second region. No updates to the data in the 8 and 64 second regions occurred, because the telemetry for that cycle was not sampled (as noted by event 5D)" [-Joe Auchter]. An Aqua Discrepancy Report (ADR) has been submitted to document the situation.
So far, there does not appear to be any recognizable pattern or discernable event that is triggering the CP to generate these event messages. Analysis of telemetry continues.
The last event set occurred at 2002/151-13:55:18.
MODIS is currently On in B-Side Standby Mode (Power Supply 2, Control Processor B) with the Space View Door at its Open Position. All 3 outgas heaters (Cold Stage, Intermediate Stage, and Outer Stage) are powered and duty cycling nominally.
The current MODIS telemetry is consistent with what is expected with MODIS in Standby Mode with Outgassing.
None
146/00:54 AIRS performs warm function checkout.
146/01:52 AIRS performs VIS/NIR Radiometric test on Lamp 1
146/02:40 AIRS performs VIS/NIR Radiometric test on Lamp 2
146/03:27 AIRS performs VIS/NIR Radiometric test on Lamp 3
CERES performs several calibration activities throughout the day.
CERES continues to perform their calibration activities.
147/15:10 AMSR/e enables their FMU taxi interface (SPS on).
148/12:57 CERES performs bi-axial internal calibration.
148/15:53 CERES performs solar calibration.
149/12:49 AMSR/e in observation mode.
CERES performs numerous checkouts and calibrations.
More CERES calibrations and checkouts throughout the day.
150/22:21 AIRS ES deployed.
150/23:15 AIRS Rad calibration on.
150/23:15 AIRS choke heater on.
150/23:40 CERES to standby.
151/11:22 HSB and AMSU parked.
151/13:05 Thrusters 1 & 2 fire test..
151/13:58 Thruster 3 fire test.
151/14:42 Thruster 4 fire test.
151/15:31 Thruster 1 fire test.
151/16:10 Thruster 3 fire test.
151/17:01 Thruster 2 fire test.
151/18:44 Thruster 4 fire test.
151/21:10 HSB and AMSU returned to normal scanning.