MAIN PAGEMODIS INFOINSTRUMENT OPSWeekly ReportsMODIS HistoryCALIBRATIONL1B PRODUCT INFO
|
MODIS IOT Terra Weekly Report
Mission Operations Days: 2007/020 through 2007/026
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
AM-1 "Terra" is in Normal Mode PFM MODIS is in A-Side Nominal Science Mode (Cross Strapped with FR B) |
||
| Component | State(s) | Comment |
|---|---|---|
| Blackbody | A On (290K); B Off | Nominal Science Mode |
| Calibration Electronics | A On; B Off | Nominal Science Mode |
| Control Processor | A On; B Off | Nominal Science Mode |
| Nadir Door | Unlatched, Open | Nominal Science Mode |
| Space View Door | Unlatched, Open | Nominal Science Mode |
| Solar Diffuser Door | Unlatched, Screened | Permanent Configuration |
| FDDI Formatter | A On; B Off | Nominal Science Mode |
| FDDI Port | A On; B Off | Nominal Science Mode |
| FIFO Memory | #1 & #2 On; #3 & #4 Off | Nominal Science Mode |
| Format Processor | A Off; B On | Nominal Science Mode |
| Power Supplies | #1 On, #2 Off | Nominal Science Mode |
| PV VIS FPA | A On; B Off | Nominal Science Mode |
| PV NIR FPA | A On; B Off | Nominal Science Mode |
| PV SMIR FPA | A On; B Off | Nominal Science Mode |
| PV LWIR FPA | A On; B Off | Nominal Science Mode |
| PC LWIR FPA | A On; B Off | Nominal Science Mode |
| RC Outgas Heaters | All 3 (CS, IS, OS) Off | Nominal Science Mode |
| RC LWIR FPA Heater | On (83K) | Nominal Science Mode |
| RC SMIR FPA Heater | Off | Nominal Science Mode |
| Scan Assembly | A On; B Off | Nominal Science Mode |
| SDSM | Off | Nominal Science Mode |
| SRCA | Off
| Nominal Science Mode |
| PS1 Survival Heater | Enabled | Nominal Science Mode |
| PS2 Survival Heater | Enabled | Nominal Science Mode |
| Timing Generator | A On; B Off | Nominal Science Mode |
| Flight Software | Rev BD + 11 sets of patches
| Nominal Science Mode |
| Inhibit Ids Set | none | Nominal Science Mode |
| TMON 66 | Disabled | Nominal Science Mode |
| TMON 67 | Disabled | Nominal Science Mode |
| TMON 68 | Enabled | Nominal Science Mode |
| TMON 69 | Disabled | Nominal Science Mode |
None
Sunday, January 21, 2007None
Monday, January 22, 2007None
Tuesday, January 23, 2007
2007/023 20:43:35-20:52:23 ATC MOD_OA16_SDSM_SCRN_NO_DOOR_A.4
OA-16: SD/SDSM screened side A, no door movement.
2007/023 23:15:00-23:15:29 ATC MOD_SRCA_9_8_2_SETUP_CC.1
SRCA setup activity using 10W lamps 1 and 4, and 1W lamp 5, in constant current feedback mode
2007/023 23:20:58-23:52:23 ATC MOD_OA19_SRCA_FULL_RAD.1
OA-19: SRCA Full Radiometric Calibration.
Data Collection 23:36:59-23:52:22 (centered on S/C Night)
S/C Night 23:28:08-00:01:12
None
Thursday, January 25, 2007None
Friday, January 26, 2007None
None
Calibrations for January will include two biweekly SDSM, one monthly Lunar Calibration Roll, one monthly SRCA Full Radiometric, one quad-monthly SRCA Full Spectral, and one quarterly PV Ecal.
Calibrations for February will include two biweekly SDSM, one monthly Lunar Calibration Roll, one monthly SRCA Full Radiometric, and one trimonthly SRCA Full Spatial.
The next Terra MODIS Lunar Calibration Roll will be on DOY 2007/038 (February 7, 2007). The roll angle will be -11.2452 degrees. Data collect will be from 02:53:57-03:00:27.
None
MODIS is in Science Mode, using all A-side components, but cross-strapped to Formatter B, with the blackbody maintained at 290K and the Solar Diffuser Door at the Screened position.
Nominal telemetry trending is ongoing.
The EMOS mission status webpage (which includes instrument data loss records) can be found at the following URL. Note that a password is now required to access the EOS mission links web pages. There are directions at the URL below for how to obtain a username/password.
http://jupiter02.gsfc.nasa.gov/links/links.htm
SRCA 10W Lamp #1: 257.8 of 500 hours
SRCA 10W Lamp #2: 172.1 of 500 hours
SRCA 10W Lamp #3: 190.3 of 500 hours
SRCA 10W Lamp #4: 82.2 of 500 hours
SRCA 1W Lamp #1: 571.0 of 4000 hours
SRCA 1W Lamp #2: 278.7 of 4000 hours
Solar Diffuser Door: 2146 of 3022 Movements
Nadir Aperture Door: 540 of 1316 Movements
Space View Door: 443 of 1316 Movements
Email the MODIS IOT
to report any problem with the MODIS IOT Web Pages.
Email the MCST Webmaster
to report any problem with the MCST Web Pages.
Email the MCST Helpdesk
to ask a question about Level 1B usage, algorithms or software.